Everything an engineer needs to specify a magnet: which grade holds its flux at your temperature,
which coating survives your environment, and what tolerance we can hold on your dimensions.
NdFeB
N35–N56 · M / H / SH / UH / EH / TH · 80–230 °C · Br up to 1.50 T
The same geometry can behave very differently at temperature. Choosing a grade with enough
intrinsic coercivity for your worst-case temperature is the single most important specification decision.
N (80 °C) and M (100 °C) — room-temperature duty, best flux per dollar
H (120 °C) and SH (150 °C) — motors, sensors and automotive auxiliaries
UH (180 °C), EH (200 °C) and TH (230 °C) — harsh or high-load environments
SmCo when temperature exceeds 250 °C or corrosion resistance is critical
Typical coating performance for sintered NdFeB. Salt-spray (NSS), humid-heat, PCT/HAST and maximum
service temperature are listed for each system.
Coating
Thickness (μm)
Neutral Salt Spray (h)
Humid Heat (h)
PCT / HAST (h)
Max Use Temp (°C)
Zinc (Zn)
5–15
≥48
—
—
≤160
Nickel (Ni)
10–30
≥96
≥500
96
≤200
Ni + Sn
10–30
≥96
500
96
≤200
Ni + Au
10–30
≥96
500
96
≤200
Ni + Ag
10–30
≥96
72
48
≤160
Epoxy
10–30
≥72
72
48
≤160
NiCu + Epoxy
20–40
≥500
500
200
≤160
Ni + Epoxy
20–40
≥500
500
200
≤160
Vacuum-plated Al
5–30
≥100
500
200
≤400
Al + Epoxy
15–30
≥200
500
200
≤160
Corrosion resistance also depends on part geometry — edges and sharp corners
corrode first. Share your drawing and we will recommend a coating system.
Magnetization
Magnetization Directions
Direction determines how the flux leaves the part — and it must be fixed before tooling.
We magnetize square blocks along length, width or thickness; rings axially or radially; and tiles
radially, through width or through thickness.
▭
Square & Block
Along length, width or thickness.
◯
Ring & Cylinder
Axial, radial or multi-pole.
◗
Tile & Arc
Radial, width or thickness.
Tolerances
Machining Tolerances (mm)
Standard achievable tolerances for blocks, discs, rings and arcs. Tighter values are possible on
request, depending on size and coating.
Size range
Dimensions
Geometry
Outer Ø
Inner Ø
Length L
Width W
Thickness T
Flatness
Parallelism
Perpendicularity
Roundness
Concentricity
≤ 5 mm
0.03
0.05
0.04
0.04
0.04
0.02
0.03
0.03
0.02
0.04
5 < L ≤ 30 mm
0.05
0.06
0.06
0.06
0.06
0.02
0.04
0.05
0.02
0.05
30 < L ≤ 70 mm
0.08
0.1
0.08
0.08
0.08
0.04
0.06
0.1
0.03
0.1
70 < L ≤ 120 mm
0.08
0.15
0.1
0.1
0.1
0.04
0.08
0.15
0.05
0.15
120–200 mm
0.15
0.18
0.15
0.15
0.15
0.06
0.12
0.3
0.06
0.3
Values are typical production tolerances in millimetres for uncoated parts;
plating adds 10–30 μm per surface depending on the system.
Curves
Demagnetization Curves
B-H and J-H curves measured at elevated temperature — use them to check your working point and
load line.
Grade 42EH 20–200 °C
Grade 35AH 20–200 °C
Grade 45UH 20–180 °C
Grade N50H 20–120 °C
Grade N50M 20–100 °C
Need A Data Sheet?
Tell us the grade and geometry you are considering and we will send the matching curve, tolerance and coating data.